DANFOSS Drivesdanfoss drivers

 

fc51VLT® Micro Drive FC 51

Small dimensions and “book” design allow a high degree of integration and saving space in the cabinet

Wide range of integrated functions.

Intelligent cooling mode and coated circuit boards ensure reliable operation even in harsh environments.

Power range

  • 1 x 200-240 V................................0,18-2,2 kW
  • 3 x 200-240 V...............................0,25-3,7 kW
  • 3 x 380-480 V............................... 0,37-22 Kw

Integrated fieldbus: Modbus RTU
Degree of protection: IP20, IP21 / Type 1


fc280VLT® Midi Drive FC 280

The strengths of the VLT® Midi Drive FC 280 are control performance, safety functions and fieldbus communication flexibility. The integrated harmonic mitigation, the RFI filter, the double channel STO functional safety and the braking chopper avoid the need for additional space and budget for the installation of additional components.

Easy to use

A USB port allows easy connection to the PC. The VLT® Memory Module MCM 102 option facilitates rapid implementation of factory settings, transfer of settings and commissioning.

Easy retrofit

The VLT Midi Drive is designed to be compatible with the VLT® 2800. The dimensions, the plug-in connectors, the cable lengths and the software configuration tools facilitate the retrofit of existing systems or machines.

Power range

  • 1 x 200-240 V .............................. 0,37-2,2 kW
  • 3 x 200-240 V............................... 0,37-3,7 kW
  • 3 x 380-480 V............................... 0,37-22 kW

Integrated fieldbus: Modbus RTU
Degree of protection: IP20, IP21 / Type 1


ld302VLT® Lift Drive LD 302

Suitable for both cable and hydraulic lifts, the VLT® Lift Drive operates in open or closed loop systems.

Uniform, silent and safe

Maximum safety is a standard for all VLT® converters, while comfort is our top priority. With a high switching frequency, the internal cooling fan with optimized control and no motor contactor, the VLT® Lift Drive ensures quiet operation with low sound emissions and high reliability.

Works without motor contactors

The integrated Safe Stop function meets the safety standards of the conventional version with two contactors for the elevators. This patented feature paves the way for new opportunities, especially for elevators without a machine room.

Operation with any type or brand of traditional motor

Regardless of the type or brand of the motor, the static automatic motor adaptation (AMA) allows simple commissioning without having to remove the ropes from the drive pulleys.

Power range

  • 380-400 V................................................ 4-55 kW

Grado di protezione: IP20, IP21/Tipo 1, IP55/Tipo 12


fc103VLT® Refrigeration Drive FC 103

Dedicated to the control of compressors, pumps and fans, it ensures significant energy savings in refrigeration systems, while prolonging the life of the components.

COP (coefficient of performance) improved

Intelligent power regulation increases the stability of the system and optimizes the volumetric efficiency of the evaporator, the compressor and the entire refrigeration system. Compressor life is prolonged by reducing the number of starts and stops and continuously adapting the cooling capacity to the needs, thus maintaining a stable temperature.

Refrigeration terminology

The use of the typical terminology of the refrigeration sector allows a quick and simple configuration.

Serial frequency converter

The combination of variable-speed compressors and mains-powered compressors enables the design of low-wear and energy-efficient systems.

Power range

  • 3 x 200-240 V....................................... 1,1-45 kW
  • 3 x 380-480 V...................................... ,1-560 kW
  • 3 x 525-600 V...................................... 1,1-90 kW
  • 3 x 525-690 V.................................... 75-800 kW

Integrated fieldbus: Modbus RTU, Metasys N2
Degree of protection: IP20, IP21 / Type 1, IP54 / Type 12, IP55 / Type 12, IP66 / Type 4X


fcd302VLT® AutomationDrive FC 302

The VLT® AutomationDrive FC 302 is a modular converter designed to meet all the requirements of modern automation applications with a simple configuration and a wide power range.

Security where needed

The VLT® AutomationDrive FC 302 is equipped with the Safe Torque Off system as standard. Easily configurable options are available: SS1, SLS, SMS and SSM.

Integrated Motion Controller

The Integrated Motion Controller software allows VLT® Automation-Drive FC 302 to operate induction and permanent magnet motors in positioning and synchronization applications, with or without encoder.

Harmonic mitigation

Advanced active filter variants, at best, reduce harmonics to below 3%, while 12-pulse converters offer significant and cost-effective harmonic reduction in power applications.

Power range

  • 3 x 200-240 V.................................... 0,25-37 kW
  • 3 x 380-500 V................................0,37-1100 kW
  • 3 x 525-600 V....................................0,75-75 kW
  • 3 x 525-690 V..................................1,1-1400 kW

Power range -Low Harmonic Drives

  • 3 x 380-480 V.................................. 132-450 kW

Power range - 12-pulse Drive

  • 3 x 380-500 V.............................. 250-1.000 kW
  • 3 x 525-690 V...............................250-1.400 Kw

Integrated fieldbus: Modbus RTU
Degree of protection: IP00, IP20, IP21 / Type 1, IP54 / Type 12, IP55 / Type 12, IP66 / Type 4X


fc202VLT® AQUA Drive FC 202

The VLT® AQUA Drive FC 202 drives and controls all types of pumps. In addition to the widely used centrifugal pumps (quadratic counter-torque), the VLT® AQUA Drive FC 202 is ideal for controlling volumetric pumps or eccentric screw pumps (constant load torque).

Attention to water and pumps

Dedicated functions, such as monitoring the bursting of pipelines, protection against dry running and flow compensation, ensure and enhance your pumping application regardless of engine technology.

Cascade controller as standard

The cascade controller as standard connects or disconnects the pumps as required and according to specified limits. It also allows master / follower operation. Optional features are available.

Power range

  • 1 x 200-240 V........................................1,1-22 kW
  • 1 x 380-480 V...................................... 7,5-37 kW
  • 3 x 200-240 V....................................0,25-45 kW
  • 3 x 380-480 V..............................0,37-1.000 kW
  • 3 x 525-600 V................................... 0,75-90 kW
  • 3 x 525-690 V..................................1,1-1400 kW

Power range -Low Harmonic Drives

  • 3 x 380-480 V.................................. 132-450 kW

Power range- 12-pulse Drive

  • 3 x 380-500 V...............................250-1.000 kW
  • 3 x 525-690 V...............................250-1.400 Kw

Integrated fieldbus: Modbus RTU
Degree of protection: IP00, IP20, IP21 / Type 1, IP54 / Type 12, IP55 / Type 12, IP66 / Type 4X


fc102VLT® HVAC Drive FC 102

Intelligent and advanced control of fans and pumps for modern buildings. Inverter resistant to extreme weather conditions, offering flexibility in terms of installation, choice of motor

HVAC Inside

The VLT® HVAC Drive FC 102 enables intelligent control of building automation, guarantees operating reliability at -25 ° C and remote control from outside the air handling unit.

Optimal EMC protection

Standard integrated chokes and high-quality RFI filters ensure interference-free operation at all times. EC +
The intelligent control principle VVC + allows the use of permanent magnet or synchronous reluctance motors with efficiency equal to or greater than that of EC technology.

Power range

  • 3 x 200-240 V....................................... 1,1-45 kW
  • 3 x 380-480 V...................................1,1-1000 kW
  • 3 x 525-600 V...................................... 1,1-90 kW
  • 3 x 525-690 V..................................1,1-1400 kW

Power range - Low Harmonic Drives

  • 3 x 380-480 V................................ 110-1000 kW

Power range - 12-pulse Drive

  • 3 x 380-480 V................................ 315-1000 kW
  • 3 x 525-690 V................................450-1400 kW

Integrated fieldbus: Modbus RTU, Metasys N2, BACnet (MSTP)
Degree of protection: IP20, IP21 / Type 1, IP54 / Type 12, IP55 / Type 12, IP66 / Type 4X


fcd302VLT® Decentral Drive FCD 302

Durable decentralized frequency converter offering a high level of flexibility and functionality. It can be mounted close to the engine and is ideal for heavy-duty applications.

One-box concept

All the necessary modules and options available are contained in the converter case.

Minimize installation costs

Fewer external components and connectors mean less installation, assembly and maintenance time.

Hygienic design

The VLT® Decentral Drive FCD 302 complies with the requirements relating to ease of cleaning and hygiene.

Power range

  • 3 x 380-480 V ......................... 0,37-3,0 kW

Integrated fieldbus: Modbus RTU
Degree of protection: IP66 / Type 4X


fcp106VLT® DriveMotor FCP 106

To ensure maximum flexibility in terms of engine selection, system design and energy efficiency, choose your PM or induction motor and install the VLT® DriveMotor FCP 106.

Easy to install

Installation is simple thanks to the integrated cooling system and the adjustable motor adapter plate.

High performance

The VLT® DriveMotor FCP 106 offers a high level of flexibility and stable and energy-efficient operation, as the frequency converter automatically sets the optimal parameters according to the connected motor.

Power range

  • 3 x 380-480 V..........................0,55-7,5 Kw

Integrated fieldbus: Modbus RTU
Degree of protection: IP66 / Type 4X


DANFOSS soft starters

avviatori statici


mcd100VLT® Soft Start Controller MCD 100

The series of compact soft starters represents a valid and economical alternative to traditional contactors, which can also replace star / delta combinations. The ramp time, the starting torque and the kick start are adjusted by the controls on the front of the unit.

Almost infinite motor starters

For nominal powers up to 25 A, up to 480 starts / hour are possible. This is a genuine ready-to-use static starter for installation on DIN rails. Thanks to the exclusive contactor-type design, it is possible to carry out almost unlimited starts without derating.

Technical data

  • Input.................................3 x 208-600 V
  • Control voltage................ 24-480 V CA o CC
  • Power..................... 0,1 kW-11 kW (25 A)
  • Degree of protection: IP20
mcd201VLT® Compact Starter MCD 201 e 202

While the basic version and with VLT® Compact Starter MCD 201 starting torque is used only for starting the engine, the extended version VLT® Compact Starter MCD 202 offers additional engine protection functions, such as current limitation during engine starting.

Integrated bypass

Once the engine is started, the MCD 201 and the MCD 202 automatically connect the engine to the mains supply via the integrated bypass relay. This minimizes losses during full load operation.

Technical data

  • Entrance..................................3 x 200-575 V
  • Control voltage...................24 V CA o CC/110–440 V CA
  • Power................ 7,5 kW-110 kW (200 A)
  • Degree of protection: IP00, IP20
mcd500VLT® Soft Starter MCD 500

The VLT® Soft Starter MCD 500 is the complete solution for starting and stopping the three-phase asynchronous motors. Integrated current transducers measure motor current and provide important data to improve ramp profiles. Integrated bypass available up to 961 A.

Quick commissioning

The four-line graphic display (choice of eight languages) and the quick menu ensure simple and reliable configuration and data extraction.

Load-oriented starting

The adaptive acceleration control (AAC function), regulated according to the respective load, ensures the best possible starting and stopping ramps in order to avoid water hammering.

Complete protection

Error detection, thyristor monitoring and bypass contact overload are only some of the integrated monitoring functions.

Technical data

  • Input..................................... 3 x 200-690 V
  • Control voltage.........................24 V CC oppure 110-240 V CA
  • Power....... 7,5-850 /2.400* (1.600 A) kW
    *”Internal triangle connection"
  • Degree of protection: IP00, IP20
Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Decline all
Read more
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google Analytics
Accept
Decline
Essential
These cookies are needed to make the website work correctly. You can not disable them.
server
Accept